Sale: 30 kVA to 100 kVA Gensets
Medium to Large Commercial Units | Industrial Workshops | Educational Institutions | Retail Chains
Diesel Power Solution offers a wide range of 30 kVA to 100 kVA gensets designed to deliver high-performance, reliable, and efficient power for medium- to large-scale applications. These gensets are engineered to provide uninterrupted electricity for critical operations, commercial facilities, and industrial setups. Available in single-phase and three-phase models, they are powered by advanced Mahindra Powerol engines, offering smooth, consistent output with optimized fuel efficiency.
Performance Highlights
These gensets are designed for maximum output with minimal fuel consumption. They reduce operational costs while providing reliable power for long-duration backup requirements.
High-capacity gensets generate heat during extended operations. Our gensets include enhanced cooling mechanisms that prevent overheating, protect engine components, and extend the overall lifespan of the equipment.
Equipped with electric start systems, digital displays, and automated monitoring, these gensets allow users to operate and monitor their performance effortlessly. Even complex setups can be handled without specialized training.
Despite their higher power output, these gensets feature robust, compact frames. Optional wheel and handle attachments allow easy relocation within industrial or commercial premises. Heavy-duty enclosures also provide protection in outdoor or harsh environments.
Advantages Across 30 kVA to 100 kVA Range
- Reliable Backup Power: Supports medium-to-heavy load applications such as machinery, HVAC systems, medical equipment, and data servers.
- Safety Mechanisms: Includes low oil shutdown, overload protection, circuit breakers, and temperature sensors to ensure safe operation.
- Silent Operation Options: Acoustic enclosures reduce noise, making these gensets suitable for hospitals, schools, and residential-adjacent facilities.
- Scalable Solutions: Covers a wide range of applications—from small industries (30 kVA) to large industrial units and commercial setups (100 kVA).
Why Choose Diesel Power Solution for 30–100 kVA Gensets?
- Genuine Mahindra Powerol engines ensuring reliability and durability
- Efficient fuel usage for cost-effective operations
- Expert installation, maintenance, and repair support
- Customizable solutions for specific commercial and industrial needs
- Commitment to long-term performance and client satisfaction
| Parameters | 30 kVA | 35 kVA | 40 kVA | 45 kVA | 50 kVA | 58.5 kVA | 82.5 kVA | 100 kVA |
|---|---|---|---|---|---|---|---|---|
| DG Model | M30DR | MB35DR | M40DR | MB45DR | M50DR | M58.5DR | M82.5DR | M100DR |
| Power Rating (kWe) | 24 | 28 | 32 | 36 | 40 | 46.8 | 66 | 80 |
| No. of Phases | 1/3 | 1/3 | 1/3 | 1/3 | 3 | 3 | 3 | 3 |
| Output Voltage (V) | 230/415 | 230/415 | 230/415 | 415 | 415 | 415 | 415 | 415 |
| Power Factor | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 |
| Current (A) | 130.4 / 41.7 | 152.2 / 48.7 | 173.9 / 55.6 | 62.55 | 69.5 | 81.3 | 114.67 | 139 |
| Frequency / RPM | 50/1500 | 50/1500 | 50/1500 | 50/1500 | 50/1500 | 50/1500 | 50/1500 | 50/1500 |
| Governing Class | G3 | G3 | G3 | G3 | G3 | G3 | G3 | G3 |
| Starting System | 12 V - DC electrical | 12 V - DC electrical | 12 V - DC electrical | 12 V - DC electrical | 12 V - DC electrical | 12 V - DC electrical | 12 V - DC electrical | 12 V - DC electrical |
| Fuel Tank Capacity (Ltrs) | 115 | 115 | 115 | 115 | 156 | 156 | 169 | 250 |
| DEF Tank | NA | NA | NA | NA | NA | NA | 18L | 35L |
| Dimensions (mm) | 2325 × 980 × 1330 | 2325 × 980 × 1330 | 2325 × 980 × 1330 | 2325 × 980 × 1330 | 2600 × 1130 × 1575 | 2600 × 1130 × 1575 | 3190 × 1225 × 1275 | 3950 × 1350 × 1425 |
| Weight (kg) | 910/910 | 915/915 | 970/970 | 990 | 1200 | 1285 | 1630 | 1970 |
| Engine Specifications | ||||||||
| Engine Make | Mahindra | Mahindra | Mahindra | Mahindra | Mahindra | Mahindra | Mahindra | Mahindra |
| Engine Model | M3205G5 | M3205G5 | M4275G1 | M4275G1 | V4355G1 | V4355G2 | V4355G4 | H4485G2 |
| Fuel System | Electronic/CRDI | Electronic/CRDI | Electronic/CRDI | Electronic/CRDI | Electronic/CRDI | Electronic/CRDI | Electronic/CRDI | Electronic/CRDI |
| Rated HP | 40.0 | 40.0 | 51.8 | 51.8 | 65.4 | 75.5 | 101.3 | 126 |
| Aspiration | TCIC | TCIC | TCIC | TCIC | TCIC | TCIC | TCIC | TCIC |
| Cylinders | 3 | 3 | 4 | 4 | 4 | 4 | 4 | 4 |
| Bore × Stroke (mm) | 88.9 × 110 | 88.9 × 110 | 88.9 × 110 | 88.9 × 110 | 96 × 122 | 96 × 122 | 96 × 122 | 105 × 137 |
| Displacement (Ltr) | 2.0 | 2.0 | 2.7 | 2.7 | 3.5 | 3.5 | 3.5 | 4.7 |
| Lube Oil Spec | SAE 15W40 CI4+ | SAE 15W40 CI4+ | SAE 15W40 CI4+ | SAE 15W40 CI4+ | SAE 15W40 CI4+ | SAE 15W40 CI4+ | SAE 15W40 CI4+ | SAE 15W40 CI4+ |
| Oil Capacity (Lit) | 7 | 7 | 10.5 | 10.5 | 8.5 | 8.5 | 11.5 | 13.5 |
| Oil Change (Hrs) | 600 | 600 | 600 | 600 | 600 | 600 | 600 | 500 |
| Coolant Capacity (Lit) | 9.5 | 9.5 | 9.5 | 9.5 | 15 | 15 | 19 | 19 |
| Alternator Specifications | ||||||||
| Make (Option) | CG/LS Equivalent | CG/LS Equivalent | CG/LS Equivalent | CG/LS Equivalent | CG/LS Equivalent | CG/LS Equivalent | CG/LS Equivalent | CG/LS Equivalent |
| Type | — | — | — | — | — | Single Bearing, Brushless Type | — | — |
| Enclosure Type | IP23 | IP23 | IP23 | IP23 | IP23 | IP23 | IP23 | IP23 |
| Voltage Regulation | +/-1% | +/-1% | +/-1% | +/-1% | +/-1% | +/-1% | +/-1% | +/-1% |
| Class of Insulation | H | H | H | H | H | H | H | H |
| Max Unbalanced Load | 25% | 25% | 25% | 25% | 25% | 25% | 25% | 25% |